Quadruplex Service Drop Cable

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Henan
Validity to: Long-term effective
Last update: 2019-03-20 07:36
Browse the number: 333
inquiry
Company Profile
 
 
Product details


Applications



Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600F 600volt or less(phase to phase) at a conductor temperatures not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.






Manufacturing Standards



ASTM ICEA BS IEC NFC GB AS/NZS ASTM ICEA BS IEC NFC GB AS/NZS etc.






Construction



Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either PE or XLPE. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.






Specifications



Quadruples service drop cable meets or exceeds the following ASTM specifications:



B-230 Aluminum Wire, 1350-H19 for electrical Purposes.



B-231 Aluminum conductors, Concentric - Lay - Stranded.



B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR).



B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum.



Service Drop cable meets or exceeds all applicable requirements of IECA A-79-474.






Diagrams


























































































































































Technical Data of Rated Voltage 1kV Overhead Cable & ABC (Aerial Bundled Cable)




Goods Description




Specification



(mm2)




Conductor (No./mm)




Insulation Thickness/mm




Cable Overall Diameter/mm




20℃ Conductor



DC Resistanc



(Ω/km)




Cable Weight (kg/km)




ABC Cable, Four Cores, Aluminium Conductor, XLPE Insulation (AL/XLPE)




3×10+10




7/1.35




1.0




14.2




3.08




168.09




3×16+16




7/1.7




1.2




17.6




1.91




264.47




3×25+25




7/2.2




1.2




20.5




1.20




379.94




3×35+35




7/2.56




1.4




24.0




0.868




524.45




3×50+50




7/3.05




1.4




27.3




0.641




696.29




3×70+70




19/2.2




1.4




31.3




0.443




950.03




3×95+95




19/2.56




1.6




36.3




0.320




1287.10




3×120+120




19/2.85




1.6




39.8




0.253




1582.30




3×150+150




37/2.34




1.8




44.5




0.206




1976.74




3×185+185




37/2.56




2.0




49.6




0.164




2442.38




3×240+240




37/2.95




2.2




56.0




0.125




3176.17




ABC Cable, Four Cores, Aluminium Conductor, XLPE Insulation (AL/XLPE+Bare)




3×10+10(Bare)




7/1.35




1.0




12.9




3.08




152.85




3×16+16(Bare)




7/1.7




1.2




16.1




1.91




241.56




3×25+25(Bare)




7/2.2




1.2




19.1




1.20




352.47




3×35+35(Bare)




7/2.56




1.4




22.3




0.868




486.62




3×50+50(Bare)




7/3.05




1.4




25.6




0.641




652.13




3×70+70(Bare)




19/2.2




1.4




29.6




0.443




898.90




3×95+95(Bare)




19/2.56




1.6




34.3




0.320




1219.16




3×120+120(Bare)




19/2.85




1.6




37.9




0.253




1506.05




3×150+150(Bare)




37/2.34




1.8




42.3




0.206




1880.93




3×185+185(Bare)




37/2.56




2.0




47.2




0.164




2324.16




3×240+240(Bare)




37/2.95




2.2




53.4




0.125




3028.54